TO ENTER SERVICE MODE [WITH CUSTOMER REMOTE CONTROL]
- Press [POWER OFF => INFO => MENU => MUTE => POWER ON] keys on the remote control in sequence.
IF FACTORY REMOTE CONTROL IS AVAILABLE
- Press [POWER ON => INFO => FACTORY
FACTORY MODE TREE
- Calibration.
- Option => 18 7B 0000
- W/B.
- ADC
- VCTi => 1000
- ACC/ACM
- TEST PATTERN => 0
- BUS STOP => OFF
- CHECK SUM => 0000
- RESET
T-VNC25PEA-0009 2004/08/31