PANASONIC - PT-LC50U _ PT-LC50E _ PT-LC150 LCD PROJECTOR.
SERVICE POSITION
Because of this projectors' structure, service should be provided by turning the projector over, accordingly the screens are seen reversely during the service.
LAMP OPERATION TIME DISPLAY
SERVICE POSITION
Because of this projectors' structure, service should be provided by turning the projector over, accordingly the screens are seen reversely during the service.
LAMP OPERATION TIME DISPLAY
- Under the condition of the Lamp Cover SW 'ON', plug in the power cord.
- Input a signal.
- Connect a jumper wire between TP2007 & TP2008 on the main CBA, for over 5 seconds. [Service Mode Entry]
- Lamp operation time will be displayed.
- To exit from service mode, connect a jumper wire between TP2007 & TP2008 for over 5 seconds again, or press 'Menu' button on the remote control.
INITIALIZE EEPROM IC.
- After replacing main CBA, memory data such as history of lamp operation time will be reset. However it can be remained by installing EEPROM IC {IC2006} to replaced main CBA from original main CBA.
- After replacing EEPROM IC, be sure to perform each of the following steps in the order presented here.
- Connect a jumper wire between TP2017 & TP2018 on Main CBA. for over 5 seconds to set factory set mode. Then remove the wire.
- "FACTORY" appears on the screen.
- Connect a jumper wire between TP2017 & TP2018 again for over 5 seconds to initialize EEPROM IC. Then remove the jumper wire.
- "SELF CHECK' appears on the screen.
- Remove jumper wires and "MEMORY OK" appears on the screen.
- DC voltage adjustment: To set the standard voltage for LCD panel:
- Connect DVM to TP1904.
- Press 'Up/Dn button on the remote control to select '15.3V'.
- Press Right/Left buttons on the remote control so that the meter shows [15.3V +/-0.05VDC
All further adjustment need Oscilloscope, pattern generator and such advance testing instruments.