HOW TO ENTER SERVICE MODE
- While pressing Volume (-ve) button on the main unit, press 'INFO' button on the remote cotnrol (within 2 seconds).
- To 'Exit', switch Off the Power switch on the Main Unit or Power button on the remote control.
SERVICE MODE ADJUSTMENT
- Press 'recall' button on the remote control and press "-" Vol button on the LCD panel.
- Press button number '1' on the remote control to select for adjust.
- Self check to Exit.
SELF CHECK MODE
- Press the 'Menu' button on the remote control, and 'Down' button on the LCD panel.
- Press ON/OFF button on the panel to Exit.
HOTEL MODE ADJUSTMENT
- Press 'Vol Dn' button on the TV panel and 'AV' button on the remote control simultaneously '3' times to enter Hotel Mode.
- Set the 'Hotel Mode On' then press Exit to come out.
CHECK OF IIC BUS LINES: SELF CHECK INDICATION ONLY
- Produce TV reception screen, and while pressing 'Volume (-ve)' button on the main unit and press 'OK' button on the remote control for more than 3 seconds.
- Self check indication and forced to factory shipment settings: Produce TV reception screen , and while pressing 'Volume (-ve) button on the main unit, press 'Menu' button on the remote control for more than '3' seconds.
- Disconnect the AC cord from the wall outlet to 'Exit'.
POWER LED BLINKING AND FAULTY BOARDS.
- 1 blink => Inverter SOS => Power board.
- 2 blinks => Sub 1.8V SOS => A Board.
- 3 blinks => Sub 1.2V SOS => A board.
- 4 blinks => Power SOS => P/A board.
- 5 blinks => Sub 5V SOS => A board.
- 6 blinks => not used
- 7 blinks => not used.
- 8 blinks => not used
- 9 blinks => T'Con SOS => A board.
- 10 blinks => Sub 3.3V sense => A board.
- 11 blinks => DCDC SOS => A board.
- 12 blinks => SOS => A board.