TO ENTER SERVICE MODE
- Under the ATV source;
- Press the 'GREEN' button on the remote control.
- Press 'SELECT' on the remote control for more than '5' seconds.
- Buttons to use to proceed are illustrated in the service menu display.
SOFTWARE UPDATE
- The software tool is used to upgrade the relevant model of [MST718BE] solution. So it is unnecessary to install. Open this software and then operate as follows.
Operation Steps
- Connect the upgrade tool: the parellel line, connect the PC parellel port, the VGA line connect to TV unit VGA port, and select the TV unit to 'ANALOGUE TV' source.
- After opening the Master ISP untility [V4.0.5] software, interface appears.
- If it is for the first time to use this software tool, click 'Config' button. Confirm whether the default configuration is correct. If not, set up this configuration parameter.
- Check the 'Device' button to select "Pm25LV040' device, and double click to confirm.
- After selecting the device, click 'Read' button to read the files that need to upgrade.
- After reading files, click 'Auto' button to confirm the parameter is correct. If 'OK', click 'Run' button to upgrade the software.
- If the software update is not OK, click 'Run' button again to upgrade the software.