Thursday, July 05, 2012

EIKI - MULTI-MEDEA PROJECTOR SERVICE MODE AND LAMP REPLACEMENT



EIKI - MULTI-MEDIA PROJECTOR _  LC-XG110 | LC-XG210 | MJ7-XG11000 | MH7-XG21000.

LAMP REPLACEMENT AND LAMP COUNTER RESET.
lamp type: POA-LMP59.
Service Part Number: 610 305 5602
  • Turn OFF the projector, and disconnect AC cord.  Allow the projector to cool down fro at least 45 minutes.  
  • Loosen one screw and open the lamp cover.
  • Loosen two screws and pull out the lamp assembly by gasping the handle.
  • Replace the lamp assembly securely and tighten two screws.
  • Close the lamp cover and tighten one screw. 
  • Connect the AC cord to projector and turn ON.
LAMP TIME RESET.
Do not reset the Lamp Reset Counter, except after lamp is replaced.  The projector cannot to be turned ON with lamp cover removed, because when lamp cover is removed, the interlock switch is also released to 'Switch Off' the mains power supply.
  1. Turn the projector ON, and press Menu button, and the on-screen menu will appear.
  2. Press "UP" button to move a red frame pointer to "Lamp Counter Reset?"is displayed.  Move the pointer to 'Yes', and press the "Select" button.
  3. An other confirmation box appears, and select 'Yes' to reset Lamp Replace Counter.
Should the air filter become clogged with dust particles, it will reduce the cooling fan's effectiveness and my result in internal heat build up and short lamp life.  So it is recommended to clean the air filter after the projection lamp is replaced. 
HOW TO CHECK LAMP REPLACE COUNTER?
  • The lamp replacement indicator will illuminate  when the lamp replace counter reaches 1000 hours.  This is to indicate that lamp replacement is required. 
  • Press and Hold the Pointer "UP" on the projector for more than 20 seconds.
  • The Lamp Replace Counter is displayed on the top left corner of the screen briefly.  
SERVICE MODE ENTRY
  • To enter service mode, Press and Hold the Menu & Image buttons on the projector at the same time for more than 3 seconds.  The service menu will be appeared on the screen.
  • Select the adjustment Group number (Group) by pressing "Menu+" button or 'Image-" button, and select the adjustment item number by pressing UP | DN button, and change the data value to selected item, by pressing "Left or Right" button.
  • To exit service mode, press Power ON/OFF button on the projector or remote control unit.